Filtre à air à microparticules de qualité pour compresseur d'air
$158.921-19 Piece/Pieces
$150.97≥20Piece/Pieces
Type de paiement: | T/T,L/C |
Incoterm: | EXW,CIF,CFR,FOB |
transport: | Ocean,Land,Air |
Hafen: | Yantian,Guangzhou,Shanghai |
Ms. YUKA Filtration
Que puis-je faire pour vous?
$158.921-19 Piece/Pieces
$150.97≥20Piece/Pieces
Type de paiement: | T/T,L/C |
Incoterm: | EXW,CIF,CFR,FOB |
transport: | Ocean,Land,Air |
Hafen: | Yantian,Guangzhou,Shanghai |
Modèle: HG030
Element Serve Life: 6000~8000 Hours
Clapboard: Without Clapboard
Medium Material: Fiberglass
Flow Rate: 1.8 M³/Min
Material: Aluminum Alloy
Housing Serve Lige: 15 Years
Filtration Performance: From 5 μm To 0.01μm
Operate Temperature: 1.5~80ºc
Filtration Efficiency: 99.99%
Element Material: Sodium Borosilicate Glass Fiber
Maxi. Operate Pressure: 1.0 Mpa
Auto Drain Parts: Anti-Collision Nut
Filtration Grade: Ulpa Filter
Connection: Rc1/2"
Element Design: Without Tie-Rod
Sight Glass: Two
Specification: Dimension: 92x 83x 285mm
Type: Cartridge Filter
Unités de vente | : | Piece/Pieces |
Type de colis | : | Carton |
Exemple d’image | : |
The file is encrypted. Please fill in the following information to continue accessing it
Pourquoi avons-nous besoin d'un filtre à air comprimé?
La purification de l'air est essentielle pour tout compresseur d'air pour de nombreuses raisons. Fournir de l'air pur à vos outils pneumatiques prolongera considérablement leur durée de vie.
Lorsque vous utilisez un compresseur, chaque pied cube d'air qui le traverse contient des millions de particules étrangères, qui peuvent toutes s'accumuler et endommager ou inhiber vos outils. Ces particules comprennent des gouttelettes d'eau, des huiles, de la saleté, de la poussière, des bactéries et, potentiellement, des morceaux de métaux lourds, tels que le plomb, le mercure et le cadmium.
Si l'air passe à travers non filtré, il peut provoquer une contamination des vannes de régulation, gonfler les joints de protection et provoquer une usure prématurée, ce qui peut entraîner une défaillance de l'équipement et augmenter les coûts de réparation.
En mettant en œuvre le système de filtration approprié pour la protection et la purification, vous pouvez réduire les temps d'arrêt de la machine et le coût global, ainsi que limiter la maintenance, les réparations et la consommation d'énergie nécessaires. Mais vous devez également entretenir les filtres pour obtenir les meilleurs résultats, car des filtres obstrués ou usés peuvent provoquer une chute de pression importante, rendant votre compresseur moins efficace.
Caractéristiques et avantages
La seconde garantit le boîtier du filtre à air comprimé pendant quinze ans dans les conditions d'utilisation recommandées.
Filtration Grade | PF | AO | AA | AX | ACS | AR | AAR |
Particle removal (ISO12500-3) | 5μm | 1μm | 0.01μm | 0.01μm | - | 1μm | 0.01μm |
Outlet oil aerosol concentration (ISO12500-1) | 5mg/m³ | 0.6mg/m³ | <0.01mg/m³ | <0.001mg/m³ | <0.004mg/m³ | - | - |
Filtration performance of Particle (ISO12500-3) | - | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% |
Filtration performance of oil (ISO12500-1) | 50% | 80+% | 99.9+% | 99.99+% | - | - | - |
Element spanlife | 6000 hours | 6000 hours | 6000 hours | 6000 hours | 2000-3000 hours | 4000-6000 hours | 4000-6000 hours |
Filtration Type | Coalescence | Coalescence | Coalescence | Coalescence | Adsorption | Coalescence | Coalescence |
Airflow direction | From inside to outside | From outside to inside |
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m³/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C(clearance for housing) | ||
HG017 | RC1/2" | 16.7 | 1.0 | 35.3 | 92 | 83 | 265 | - | - | - |
HG025 | RC3/4" | 25 | 1.5 | 53 | 92 | 83 | 265 | - | - | - |
HG030 | RC1/2" | 30 | 1.8 | 63.6 | 92 | 83 | 285 | 17.5 | 193 | 158 |
HG035 | RC3/4" | 33.3 | 2 | 70.6 | 92 | 83 | 285 | 17.5 | 193 | 158 |
HG058 | R3/4" | 46.7 | 2.8 | 98.9 | 132 | 120 | 393.5 | 24.4 | 257.6 | 195 |
HG068 | RC1" | 60 | 3.6 | 127.1 | 132 | 93.3 | 393.5 | 24.4 | 257.6 | 195 |
HG080 | RC1" | 80 | 4.8 | 169.5 | 132 | 119.6 | 502 | 24.4 | 356.2 | 300 |
HG145 | RC1" | 120 | 7.2 | 254.2 | 132 | 19.6 | 502 | 24.4 | 356.2 | 300 |
Technical requirements | Maximum operating pressure: 10 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
Comment choisir le bon filtre pour votre système de compresseur d'air ?
Lorsque vous travaillez avec des compresseurs d'air, la purification et la filtration de l' air sont des éléments essentiels de la maintenance. Les filtres à air comprimé jouent un rôle important dans votre système de compresseur d'air industriel. Choisir le bon filtre augmente non seulement l'efficacité de votre unité, mais il peut également réduire les coûts énergétiques et protéger vos employés contre les produits chimiques et les particules nocifs.
Cependant, tous les filtres à air fonctionnent-ils pour votre système d'air comprimé ? Et bien c'est selon vos conditions de travail , le projet que vous réalisez et la fréquence d'utilisation de votre matériel, vous devrez faire un choix précis . Ce guide détaillera le fonctionnement des filtres de compresseur d'air, pourquoi ils sont importants , quel type de filtre de compresseur d'air acheter et quand le remplacer.
①Assess the requirements of your application. Different industry require different solution. | ||||||||
②What type of filtration is needed? Coalecent filter material removes solid and liquied contaminants from gas streams. Particulate filter media removes solid from gas streams. Absorber media removes hydrocarbon vapors from gas streams. | ||||||||
③Any specific micron of filtration performance you required? | ||||||||
④What are the working conditions of your application? Mainly criteria of consider : Flow, working pressure, temperature,pressure loss,material of structure (stainless steel, aluminum alloy, mild steel, carbon steel) | ||||||||
⑤Filter flow rate from how much SCFM? Pressure drop should be less than **bar? For saving the cost and protect environment. | ||||||||
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.